ASTM D6677 PDF

      No Comments on ASTM D6677 PDF

14 Nov A standard method for the application and performance of this test is available in ASTM. D Tape Test. On metal substrates, a more formal. 1 Jul Buy ASTM D Standard Test Method for Evaluating Adhesion by Knife from SAI Global. ASTM D is the standard for this test method. Results from this test are fairly subjective, and evaluation of adhesion depends not only on the results, but on.

Author: Maugami Shakus
Country: Bolivia
Language: English (Spanish)
Genre: Love
Published (Last): 23 August 2012
Pages: 74
PDF File Size: 13.3 Mb
ePub File Size: 11.47 Mb
ISBN: 353-8-36117-483-1
Downloads: 91388
Price: Free* [*Free Regsitration Required]
Uploader: Zukus

ASTM D – 01 Standard Test Method for Evaluating Adhesion by Knife

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided d677 part of the standard.

According to the standard, the applied load rate should not exceed 30 psi per second, to complete the test in 5 to 30 seconds. Coating is somewhat difficult to remove; chips ranging from approximately 3.

The following devices are in accordance with ISO Monitoring Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work.

The version of ASTM D underwent significant changes that impact how the testing is performed and how the data are interpreted. One characteristic that is common to all test methods, and perhaps the most difficult part, is selecting the appropriate test area 6d677.

Finally, while concrete has high compressive strength, it frequently exhibits low tensile strength e. Coating can be easily peeled from the substrate to a length greater than 6. The test areas should be free of grease, oil, dirt, chalking paint, and surface moisture, as these will interfere with the testing procedures.

  STEPHEN COVEY THE THIRD ALTERNATIVE EPUB

We use cookies to understand how you use our site and to improve your experience. The following devices are in accordance with BS If the document is revised or amended, you will be notified by email.

ASTM D6677 – 18

Managing glue breaks is particularly notable and is bolded and italicized for emphasis below. For large large structures structures make suff sufficient icient tests tests to ensure ensure that the adhesion evaluation is representative of the whole surface.

The following devices are in accordance with BS standards: The values given in parentheses are for information only. To reduce this effect, proper scoring and test fixture alignment techniques should be employed, and low loading rates should be avoided to reduce the time the elastomeric coating is under stress. You need to log in before adding standards to the monitoring service.

Characterizing a test area based on an apparent low or high individual result should be done with caution. Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. Coating is somewhat difficult to remove; chips ranging from approximately 3. Thank you for interesting in our services.

Assessing Coating Adhesion

Your Alert Profile lists the documents that will be monitored. A nonmandatory Note Note 6 was added to provide further direction to the user when considering scoring. The pull-off adhesion tests are more objective and quantitative but require test equipment and time for the glue to cure.

Please first log in with a verified email before subscribing to alerts. Rate according to Table 1.

The benefits of a subscription: Coating can be easily peeled from the substrate to a length greater than 6. There were no books found for the applied search filters. The most common errors made during the testing process lead to artificially lower results, typically not higher results.

  TRIGONO VESICAL PDF

Scoring should not be considered for coatings less than 20 mils. Current Current edition edition approved approved May 10, Note 1 The term substrate relates to the basic surface on which a coating adheres may be steel, concrete, etc. Please fill this form, we will try to respond as soon as possible. The following devices can be used in accordance with the application standard EN Need more than one copy? This includes personalizing content and advertising.

Add to Alert PDF.

We are a non-profit group that run this website to share documents. One of the most important take-aways is that the results obtained with different types of testing equipment should not be compared, even when the types of equipment are included in the standard. While the version provided a similar precaution, it only listed type of apparatus and substrate type.

Remember me for one month. They address cautions about characterizing a test area Note 11 based on high or low results and incorporating test data that f6677 glue failures in a statistical analysis Note Adhesion is evaluated qualitatively on a 0 to 10 scale. ICS Number Code The following devices are in accordance with ECE standards: The following devices are in accordance with BS A6: The following devices are in d6677 with ISO standards: