ASTM D3330 PDF

      No Comments on ASTM D3330 PDF

ASTM D/DM() includes six different test methods, depending on the specific conditions of the test and type, to be used for. Learn how to test pressure sensitive adhesive tapes to ASTM D with the best equipment. This standard is issued under the fixed designation D/DM; the number 1 This test method is under the jurisdiction of ASTM Committee D10 on.

Author: Shakajind Kagazilkree
Country: Denmark
Language: English (Spanish)
Genre: Art
Published (Last): 27 September 2018
Pages: 287
PDF File Size: 18.4 Mb
ePub File Size: 18.11 Mb
ISBN: 552-3-51500-951-8
Downloads: 18067
Price: Free* [*Free Regsitration Required]
Uploader: Kazratilar

MEGA Auto Tensile Tester is professionally designed for the determination of tensile strength, peel strength, tear strength, heat seal strength and adhesiveness of plastic films, composite films, flexible packaging materials, adhesives, adhesive tapes, pressure sensitive tapes, medical patches, protective films, release paper, rubber and paper, etc.

ASTM D Standard: 90 & Degree Peel Adhesion Tester for Pressure Sensitive Tapes

GK Mechanical Vice Grip. The liner is removed and a 0. The values stated in each system may not be exact equivalents, therefore, each system must be used independently without combining values in any way. The clamping force is all air operated giving more consistent test results, less work for the operator, less e3330 for error, and is quicker and easier for testing numerous samples.

Have a question about conducting the test for this standard? Remove a mm specimen of the tape to be tested. The P consists of a vertical load frame, an electromechanical actuator, load cell, a tocuhpad test controller, XY test software and peel grips.

ASTM D Test Method D provides a means of assessing the uniformity of the adhesion of a given type of pressure-sensitive adhesive tape. Pneumatic grips are useful for easily aligning your specimen to reduce any rubbing issues.

ASTM D / DM – 04() Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape

The area under stress varies with backing stiffness and adhesive rheology firmness. Other d33330 widths available upon request Effective and simple to use Blade replacement takes mere seconds.

  VASTAV RAMAYAN IN ENGLISH PDF

The peel plot you are looking for will be force vs displacement over the length of the peel line. Place the panel into the peel test machine grips and peel back 22 mm of the bottom half of the tape sample so that the specimen is doubled over itself at degrees. The test materials consist of preparing several strips of tape to be tested and a hard substrate, such as a metal plate.

ASTM D3330

Sign Up For Our Newsletter. This test also measures peel adhesion with a degree peel.

Standard sample widths of 0. Rated to 1 kN lbf Maximum specimen thicknesses from 10 mm to 50 mm 0. Secure the loose end of the tape with the tab qstm the upper grip.

ASTM D3330 Peel Adhesion Pressure Sensitive Adhesive Tapes

Rated to N 50 lbf Maximum specimen thickness of 8 mm 0. Apply a second strip of the tape to the backing of the first strip on the test aztm, taking care to align the edges of the second specimen with those of the strip in the test panel. They can help you configure the best test machine and grips for your specimens.

If the adherent is set on an angle, d330 will cause an error. These characteristics will result in a high variability for the test response which is not a true indication of the real nature of the adhesive bond. In a face-side application, the tape is adhered to a standard steel panel or your chosen substrate in the same manner as the previous methods mention with pressure sensitive tape. Forces up to 10 adtm 2, lbf Low force tabletop systems Modular series of five frame options with adjustable test space Affordable testing option for tension, compression, bend, peel and asm more.

XLW M Auto Tensile Tester is designed for the test of physical mechanical properties of plastic films, laminated materials, flexible packaging materials, plastic flexible tube, adhesives, adhesive tapes, pressure sensitive tapes, and adhesive bandage plaster etc.

  BULIAUS GALIA KNYGA PDF

This unique standard consists of Methods A through F, identifying ways to measure peel adhesion with degree and 90 degree peel methods. Next, clamp the substrate panel into the moveable jaw of testing machine and free end of tape into other jaw. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

MED Medical Packaging Tester MED Medical Packaging Tester is professionally applicable to the determination of force properties of various medical packaging materials, with high precision better than 0. The force will be different at other peel rates.

For ASTM D, we would configure a small capacity load cell 10 or 25 pound for this low force peel test. This software enables you to easily determine average peel force over a chosen displacement.

Simple design can be used for a multitude of tensile applications Inexpensive and reliable. XLW Auto Tensile Tester is applicable to the determination of physical mechanical properties of plastic films, laminated materials, flexible packaging materials, plastic flexible tube, adhesives, adhesive tapes, pressure sensitive tapes, adhesive bandage plasterrelease paper, protective films, flip off cap, foil, diaphragm, back sheet, non-woven, rubber, and paper fiber, etc.

If this occurs, the friction of that touching will cause errors in the peel force data. For more information on how Labthink can help your company profit through testing, please Click the button. For Method B, measure out several strips of the tape according to the standard.